SportMaster's engineering specification, CMT-53, for the ProCushion System over concrete court surfaces. The slab needs a vapor barrier, perimeter drainage and moisture curing only; new concrete cures 28 days, then is etched, repaired, primed with Acrylic Adhesion Promoter and given one (1) or more coats of Acrylic Resurfacer. The standard system adds (3) coats of CushionMaster II and (2) of CushionMaster I, the premium system (5) and (2), under a minimum of two color coats and one coat of Line Paint.

CMT-53 Revised May 2024 2 pages, 122 KB

Open the PDF Ask us about it

This is SportMaster's document, kept here so our customers and crews can read it beside our own pages. SportMaster's own copy is on sportmaster.net.

First page of the SportMaster engineering specification for ProCushion System over concrete Open the PDF (2 pages, 122 KB)

Key facts

SystemSportMaster ProCushion System
SurfaceConcrete, medium broom finish or similar roughened texture, never steel troweled
Cure before coatingNew concrete: 28 days
Cushion layersStandard: (3) coats of CushionMaster II, then (2) coats of CushionMaster I. Premium: (5) coats of CushionMaster II, then (2) coats of CushionMaster I
Color coatsA minimum of two coats of the SportMaster Color Coating System
Line markingLaid out according to the relevant sport organization instructions

Taken from this document. The PDF is SportMaster's official document (CMT-53, revised May 2024).

The full text of this document

This is the document's own text, moved from the PDF by machine, word for word, and checked against it. The PDF is SportMaster's official document (CMT-53, revised May 2024). If the two ever differ, the PDF is right.

Engineering Spec Sheet · CMT-53 · REVISED 05/24 · Specifications for applying · SPORTMASTER PROCUSHION SYSTEM · over Concrete Court Surfaces

PRODUCT NAME

SportMaster ProCushion System over concrete court surfaces.

DISTRIBUTION LOCATIONS

SportMaster products are distributed through a worldwide network of stores and distributors. Call (800)395-7325 or visit www.sportmaster.net to find a location near you.

1. SCOPE:

1.1 The following specifications pertain to the application of the SportMaster ProCushion System over concrete court surfaces. Refer to Product Technical Data sheets for specific mixing and application instructions.

1.2 SportMaster color coating systems are designed for use on properly built sport surfaces. Refer to the American Sports Builders Association for recommended guidelines on construction of court surfaces.

1.3 The concrete surface must be constructed with a suitable vapor barrier beneath the slab and adequate perimeter drainage to prevent moisture accumulation beneath the surface. Do not use curing compounds on the concrete surface. Moisture curing only.

2. SURFACE PREPARATION:

2.1 New concrete surfaces must cure 28 days. Concrete surfaces should have a medium broom finish or similar roughened texture. They must never be steel troweled. If using a shot blaster to achieve texture, a shot blast profile of CSP 3 or 4 is recommended.

2.2 Thoroughly remove all dust, dirt, debris and loose materials.

2.3 Etch concrete surface with phosphoric or muriatic acid solution. Rinse clean with water after etching is complete.

2.4 Fill all cracks with SportMaster CrackMagic, Acrylic Crack Patch, Acrylic Patch Binder or other suitable crack fillers.

2.5 Repair spalled areas and level depressions or “bird baths” (1/8 inch or deeper) with SportMaster Acrylic Patch Binder or Acrylic Resurfacer patching mix.

2.6 Apply SportMaster Acrylic Adhesion Promoter or suitable primer over new or uncoated surfaces.

2.7 Apply one (1) or more coats of Acrylic Resurfacer to provide a smooth underlayment for application of the SportMaster ProCushion System.

3. APPLICATION OF PROCUSHION SYSTEM LAYERS:

3.1 Over properly prepared surface, apply (3) coats of CushionMaster II followed by (2) coats of CushionMaster I for the standard ProCushion system. For the premium ProCushion system, apply (5) coats of CushionMaster II followed by (2) coats of CushionMaster I.

4. APPLICATION OF SPORTMASTER COLOR SYSTEM:

4.1 Over properly prepared cushion layers, apply a minimum of two coats of the SportMaster Color Coating System in accordance with manufacturer’s mixing and application instructions.

5. LINE MARKINGS:

5.1 Line markings shall be laid out according to the relevant sport organization instructions.

5.2 After masking tape has been laid, apply SportMaster Stripe Rite line primer to seal voids between masking tape and court surface to prevent “bleed under” when SportMaster Line Paint is applied.

Page 2

5.3 Apply a minimum of one coat of SportMaster Line Paint.

6. GENERAL:

6.1 All work shall be performed in a workman like manner. All containers and debris shall be removed from job when completed.

Copyright© 2020, SportMaster
All rights reserved.

ThorWorks Industries, Inc.
P.O. Box 2277
Sandusky, OH 44870

Phone: 1-800-326-1994 FAX: 1-419-626-5477 www.sportmaster.net

Free estimates

Planning a court or a surface?

Industrial Surface is a SportMaster authorized installer in Northeast Ohio. Send the address and what you have in mind; we walk the site, measure it, and send a written proposal with the scope spelled out.

The yard

4000 East 86th Street, Cleveland, OH 44105

Off Broadway Avenue, south of downtown, ten minutes from I-77 and I-490.

Serving Cuyahoga, Summit, Lake, Lorain, Medina, Geauga, Portage, Stark and Ashtabula counties. Municipal, school, club, HOA and commercial work; residential courts by the job.